How to establish communication between computer and s7-200 with usb-ppi cable

1. Power on the CPU Connect the CPU and computer
2. Open the programming software and click Set PG / PC Interface in the lower left corner
Note here:
(1) If the original Siemens USB-PPI, then select PC / PPI CABLE (PPI)
And set to USB in the properties local connection
(2) If it is a non-Siemens USB-PPI, then set the corresponding COM port in the attribute local connection, such as: COM3, etc.

usb ppi cable s7-200 driver download

usb-cif02 driver download

USB-CQM1-CIF02 programming cable driver

USB-CQM1-CIF02

The USB-CQM1-CIF02 programming cable is emulated into a traditional serial port (commonly known as COM port) through the USB port of the computer, thereby using various existing programming software, communication software and monitoring software. The working power of this cable is taken from the USB port and is no longer powered by the programming port of the PLC. The LED on the converter box indicates the data transmission and reception status. The USB-CQM1-CIF02 cable is suitable for OMRON CPM1/CPM2/CPM1A/CPM2A/CQM1 series. PLC

USB-CIF02 DRIVER DOWNLOAD

USB-QC30R2 programming cable driver

USB-QC30R2 programming cable driver installation instructions

usb qc30r2 driver download

Overview

The USB programming cable communicates with the Q-series PLC via the USB-QC30R2 programming cable by emulating the computer’s USB port into a traditional serial port (usually COM3).

Features

● Supported operating systems Windows XP/ Windows2000

● Compatible with USB V1.1 V2.0

● Baud rate: 300bps ~ 1Mbps automatic adaptation

● Only one USB programming cable is supported per PC

System Requirements

Please make sure your computer is IBM PC compatible and has the following minimum system requirements before using the USB programming cable:
● Intel compatible with 586DX4-100MHz CPU or higher

● A standard USB interface (4-pin A-type socket)

Driver installation

The installation of the driver is very simple, just follow the prompts. Take Windows XP as an example, follow these steps:

1. Open the computer and insert the driver CD.

2. Plug the USB-QC30R2 cable into the computer’s USB port. Windows will detect the device and run the Add New Hardware Wizard to help you set up the new device and click Next to continue.

If Windows does not prompt for new hardware, in the Device Manager’s Hardware list, expand Universal Serial Bus Controller, select the USB device with the question mark, right-click and run the update driver.

3, Windows will detect the installation information, and the following does not pass the USB-QC30R2 driver installation instructions _ library download https://www.wenkuxiazai.com/doc/1ad4d6a8aaea998fcc220e97.html Windows logo test information box, click “still continue “.

4. Continue the installation and let Windows copy the driver files to your hard drive.

5. When Windows displays the Found New Hardware Wizard, click Finish to complete the installation.

6. After the installation is complete, please confirm that “Prolific USB-to-Serial Comm” appears in the “Port\(COM and LPT)”\Expand entry in the “Start\Control Panel\System\Hardware\Device Manager” menu of Windows. COMx)”, this COMx is the COM port number used by the USB programming cable. The port number is related to the computer. It is usually COM3 or COM4. The COM port will appear when you insert the programming cable every time you use it. You only need to use the programming software or The COM port number can be selected by selecting the application software such as communication software.

Driver removal

The driver is deleted to release the COM port resources for use by other devices, or to remove the driver and then reinstall it. Follow the steps below to remove the driver:

1. Unplug the USB programming cable from your computer.

2. Run the DRemover98_2k.exe program under the driver CD.

3. Display the prompt window and click the “OK” button.

Mitsubishi PLC programming line USB-SC09 and USB-SC09-FX difference

The difference between Mitsubishi PLC programming line USB-SC09 and USB-SC09-FX is:
1. USB-SC09-FX is only used for Mitsubishi FX series, and USB-SC09 is used for Mitsubishi FX series and A series.
2, USB-SC09-FX technology price is 140/10PCS, USB-SC09 technology price is 150/10PCS.
3. The USB-SC09-FX cable has a length of 2.5 meters and the USB-SC09 cable has a length of 3.0 meters.

Why is the USB-SC09-FX data cable for Mitsubishi FX1N-24MR PLC not connected?

After installing the driver, plug in the programming line, right click “My Computer” – “Properties” – “Hardware” – “Device Manager” – you will see “Port (COM and LPT)” in the open Device Manager window Open “Port (COM and LPT)” and you will see the COM port occupied by your programming line.

Open Mitsubishi programming software GX Developer, click menu “Online” – “Transfer Settings”, select RS-232 (not USB) in the “PC I/F” of the transfer setting, COM port is the COM port occupied by the programming line, transfer Speed is optional (default is 9600 in device management). Confirm

Usb-sc09 driver supports win8?

1. Right-click on the blank space on the desktop, and the “All Apps” option will pop up below the desktop. Left click on “All Apps”.
2. Left click on “Control Panel”.
3. The second type enters the “Control Panel” method. Press the “Windows” and “X” keys on the keyboard at the same time and click “Control Panel”.
4. Left click on “Hardware and Sound”.
5. Left click on Device Manager.
6. Left-click on the device class to be updated, right-click the device name, and left click on “Update Driver Software”.
7, update the driver can choose to automatically update online and manually specify the driver location update, select automatic update below.
8, the system will automatically find matching driver installation online.
9, update the driver can choose online automatic update and manually specify the drive location update, the following choose to manually specify the drive location update.
10. Click “Browse”.
11. Select the drive location directory and click OK.
12. Click “Next”, the system will automatically install the selected driver, and the installation steps are completed.
Step 10, please select the directory where the device driver is located according to the actual situation.

Usb-sc09 driver

USB-sc09 is connected to the computer and PLC, the driver is installed, how can I not connect?

USB-SC09 is the programming cable of Mitsubishi PLC. Before using it, you must first install the driver of the programming cable. After the installation driver is finished, you need to make a simple setting.
The setting method is as follows.
1. Right click (My Computer) and click Properties. The (System Properties) dialog box is displayed, select the hardware, and click (Device Management).
2. Select (port), find the USB port you installed, right click to display (property) click, display the property dialog bar, select (port setting) to set the COM port of the advanced setting in this dialog box to be the PLC programming software. The settings in it are the same.
3, the baud rate setting problem needs to be consistent with the baud rate of the PLC.

Of course, hardware problems or computer USB interface problems will also be caused.