Support
The SC-09 programming cable is a conversion cable from the RS232 interface (commonly known as a COM port) to RS422 interface. It is commonly used in Mitsubishi A series and FX series (FX2/FX2C/FX2N/FX0/FX0N/FX0S/FX1N/FX1S…) PLC, support All communication protocols, for computer-to-PLC programming communication and various PC monitoring software, and can replace the Mitsubishi communication module FX-232AW (or FX-232AWC), the RS422 port and RS232 port of the cable have built-in ± 15kVESD protection circuit , can be charged and plugged in any way.
If you are communicating with a Mitsubishi F1/F2 series PLC, you need to install the F2-20GF1 communication module.
If your computer uses a USB port, please use the USB interface programming cable USB-SC09.
The main technical parameters:
• Both the RS422 port and the RS232 port have a 15kVESD protection circuit that can be plugged and unplugged at any time.
• Baud rate: 0 to 230kbps adaptive
• Cable length: 3 m, fully shielded, with ground wire
• With communication indicator, LED flashes during communication
• Operating temperature: -20 ~ 75 ° C