QC30R2 or USB-QC30R2
Category: how to
What is the difference between the Mitsubishi PLC programming cable SC and the programming cable USB interface?
Computer side of the SC09 programming cable of Mitsubishi PLC is the RS232 serial 9-hole plug. Computer side of the SC09-USB programming cable of Mitsubishi PLC is a USB plug, and the driver needs to be installed. Both functions are the same
USB-QC30R2, what is the Mitsubishi programming cable used for?
USB-QC30R2 is the PLC programming cable of Mitsubishi Q series, USB port! You can download, upload programs, and monitor online the Q series PLC.
Mitsubishi PLC programming cable FX-USB-AW (USB-RS422) driver
How to make Mitsubishi programming USB cable, need to install driver to work?
How to make Mitsubishi programming USB cable, BSB end 2 pin and D9 pin connector 3 pin, BSB end 3 pin and D9 pin connector 2 pin, BSB end 5 pin and D9 pin connector 5 pin Docking, BSB end 4 feet and BSB end 6 feet shorted, D9 pin connector 6 and D9 pin connector 4. Connected to the line is OK, can be downloaded. No driver installed
Can the Mitsubishi FX3U series PLC download the program using the SC09 data cable?
Absolutely okay.
Both the FX series and the A series PLC can use SC09, not only FX2n, but others.
From FX0S to FX3U, including FX2 and A series (with 25 pins)
In addition, the Q series programming port is 6 pins of RS232, which is completely different from the 8 pin of RS422 of the FX series.
Mitsubishi PLC FX2N-64MR communicates with the computer and is connected with the SC-09 cable. Why can’t the computer collect data?
Open the PLC software, click on the online-click to read, select FXCPU, the communication COM settings are the same, the transmission speed PLC is set to 9.6, the read PLC switch is placed in the running state, and the write PLC switch is placed in the stop state.
What is the role of the 25-pin connector in the Mitsubishi SC-09 data line?
SC-09‘s multi-function data download line, 25-pin is the head-to-head method, and 25 is the connector for the 8-pin download port.
25-thread cable, available for connection to Mitsubishi A series PLC
Round 8-pin connector can be used to connect the plc of the Mitsubishi fx series
How many pin data lines are used in the Mitsubishi plc fx series jacks?
8-pin round S-terminal, but only 4 pins are actually used inside.
How to realize the communication connection between Mitsubishi FX1S series PLC and computer?
The USB-SC09 is a programming cable for Mitsubishi PLC. The driver for the programming cable must be set up before use.
After the installation driver is finished, make a simple setup.
The setting method is reproduced below. Right click (My Computer) and click Properties. The (System Properties) dialog box is shown, select the hardware, and click (Device Management).
Select (port), find the USB port you installed, right click to display (property) click, display the property dialog bar, select (port setting) to set the COM port of the advanced setting in this dialog box to be in the PLC programming software. The settings are the same ones.
What cable can the Mitsubishi FX-2n series PLC use to connect to the computer?
Mitsubishi plc programming cable, generally use usb-sc09
Mitsubishi PLC and computer USB connection can not communicate ES:01802007
1, the corresponding USB driver is not installed.
2; the reason for the line.
3; communication port selection settings.
To use a line with two integrated blocks, there is a crystal inside, otherwise it cannot communicate with the PLC.