The programming cable type of the FX series PLC is SC-09 cable or USB-SC09-FX cable.
SC-09 is used to connect to the computer serial port. USB-SC09-FX is connected to the computer USB port
Category: how to
Mitsubishi version 8.86 is installed in 90% and cannot be applied on 64-bit platforms.
My Mitsubishi 8.86 version is installed in 90%. It can’t be fitted to a 64-bit platform. Installation can be expected to be completed, that is, the USB communication cable driver cannot be installed.
90% happen to be a USB driver installation.
“Cannot run an x86 build of this utility on x64 platform ”
Click to confirm that internalizing driver failed —-C.windows\temp\wdreg.exe.Error,”
The installation is properly the driver installation fails when the USB communication cable (USB-SC09+) is installed.
My computer WIN7 64-bit original home version with everyone said the method of upgrading to the flagship version of the installation results
I installed a low version of GX Developer 8.52 Mitsubishi Chinese also appeared this symptom, my system win 7 64-bit ordinary home version upgrade flagship version; I found online 8.9.1 can support win 7
I am using the Mitsubishi Q series PLC. Is there any special model for the USB programming data cable?
Model QC30R2
Shielded with magnetic ring
The reliability of transmitting data is better
Mitsubishi plc programming software v8.86 what programming cable
Mitsubishi plc programming software uses the SC09 serial cable or the USB-SC09 cable.
How does the Omron CP1E-PLC communicate with the computer?
Programming with CXProgrammer, all the options for installing CX-One, it will automatically install the driver. Omron PLC does not need to choose com port like Mitsubishi. When the driver is automatically installed, it can communicate directly with the PLC via USB.

In the figure above, the USB programming port is the D port on the left. This is the most common communication method. If you add a network cable to the serial port, then you can also set it through the network cable.
How to use a computer to connect AB PLC
First open the RS LINX software and it will automatically scan to the PLC you are connected to. If it is just a monitoring program, then directly open the lower software, online.
If it is a new module, first set the CPU IP with BOOTP/DHCP (modify the IP for the old module can also be modified in RS linx), then use ControlFLASH to brush the hardware (must be the same as your lower computer version)
After you finish, you can use the program to download normally.


How to copy out the program from Xinjie plc?
Copy the program steps in plc:
1: Connect the data cable of the computer with a dedicated PLC from Xinjie.
2: Install the PLC programming software of Xinjie, find the uploaded function upload after power-on.
3: If there is a password (in most cases, the programmer will set a password), the password can be uploaded, and the password can be uploaded without a password.
Mitsubishi FX1s PLC computer communication method, (detailed steps) and communication line to USB/RS422, can’t use RS232?
I am using the communication serial port USB to 232
There is also a drive CD, which is to be installed.
Select the corresponding port when communicating with the PLC.
USB-SC09 is the programming cable of Mitsubishi PLC. Before using it, you must first install the driver of the programming cable. After the installation driver is finished, you need to make a simple setting. The setting method is as follows. 1. Right click (My Computer) and click Properties. The (System Properties) dialog box is displayed, select the hardware, and click (Device Management). 2. Select (port), find the USB port you installed, right click to display (property), click to display the property dialog bar, select (port setting) to set the COM port of the advanced setting in this dialog box to be the PLC programming software. The settings in it are the same.
How to download FX1s program to Fx3sAPLC
1. Open the FX1S project with GX2 first.
2. In the “Project” menu, click “Change PLC” pop-up dialog box to select FX3S and then confirm, the system will automatically convert!
3, waiting for the conversion is complete, compile under the line.
4, connect FX3S download program on the line
Which version of software does Mitsubishi use to write the fx3sa program?
Mitsubishi CPU module FX3U-32M is 16-point input / 16-point output; expansion module FX2N48R is 24-point input / 24-point output is 40 input / 40 output. You can choose Mitsubishi CPU module FX2N-80MR, host 40 in / 40 out relay Output or CPU module FX3U-80MR, host 40 in / 40 out relay output CPU module does not have to choose relay mode output, can also choose transistor output
What is the difference between fx 2n plc and the 3u series?
1, 2N can not drive servo or stepper motor, 3U can drive 3 servos or steps, that is to say, high-speed buy punch (y0, y1, y2)
2, program capacity, 2N seems to be 16,000 steps, 3U seems to be 64000 steps
3, Allow 2/268 I/O points, 3U can control up to 254 input/output I/0
What is the difference between Mitsubishi PLC FX3U and FX3G?
The complement of the points, the shape is a little different, everything else is the same,
3U is 16 32 48 64 80 128, 3G is 14 24 40 60
3u is a substitute for 2n, 3G is a substitute for 1n