You should check the port number of your USB programming cable that is visualized in the port of the hardware manager, such as COM8, then set it to COM8 in the programming software.
In general, COM4 or above will be visualized on the notebook, and COM6 or above will be visualized on the desktop.
Category: Mitsubishi PLC Cable
Mitsubishi PLC Cable
Why does Mitsubishi fx not use rs422 instead of rs232
The programming port of the FX1S (8-pin round port) is RS422 serial communication.
Use of usb-sc09-fx communication cable and click “RS-232”.
The COM port should choose the COM port that the communication cable actually occupies.
RS232, RS422, RS485 are distinct serial communication formats.
The computer is RS232 (DB9 pin) communication, the general notebook uses USB,
Can USB-RS422 connect directly to the PLC?
I use the Mitsubishi FX series PLC and the computer of Tsinghua Tongfang Fengrui 42A. I bought a USB-SC09-FXUSB-RS422 cable and also brought a CD. I installed it but could not communicate with the PLC.
It should work well, this cable 422 port has MD8M plug, plug in the PLC communication port, set the communication parameters to download the program (FX series PLC). Note that the local cable should be set to connect local connection to USB.
That is, parameters such as the baud rate should be set the same. Is that your local connection is the default one of the COM ports, and you select USB.
Is the FX3u and FX2n programming cable shared? Is it SC09?
Support
The SC-09 programming cable is a conversion cable from the RS232 interface (commonly known as a COM port) to RS422 interface. It is commonly used in Mitsubishi A series and FX series (FX2/FX2C/FX2N/FX0/FX0N/FX0S/FX1N/FX1S…) PLC, support All communication protocols, for computer-to-PLC programming communication and various PC monitoring software, and can replace the Mitsubishi communication module FX-232AW (or FX-232AWC), the RS422 port and RS232 port of the cable have built-in ± 15kVESD protection circuit , can be charged and plugged in any way.
If you are communicating with a Mitsubishi F1/F2 series PLC, you need to install the F2-20GF1 communication module.
If your computer uses a USB port, please use the USB interface programming cable USB-SC09.
The main technical parameters:
• Both the RS422 port and the RS232 port have a 15kVESD protection circuit that can be plugged and unplugged at any time.
• Baud rate: 0 to 230kbps adaptive
• Cable length: 3 m, fully shielded, with ground wire
• With communication indicator, LED flashes during communication
• Operating temperature: -20 ~ 75 ° C
Win7 64-bit Mitsubishi PLC usb to RS422 driver
Usb-sc09 driver supports win8?
1. Right-click on the blank space on the desktop, and the “All Apps” option will be displayed below the desktop. Left-click on “All Apps”.
2. Left-click on “Control Panel”.
3. The second type gets into the “Control Panel” method. Press the “Windows” and “X” keys on the keyboard at the same time and click “Control Panel”.
4. Left-click on “Hardware and Sound”.
5. Left-click on Device Manager.
6. Left click on the device class to upgrade, right-click the device name, and left click on “Update Driver Software”.
7, upgrade the driver can choose to automatically update online and manually specify the driver location update, select automatic update below.
8, the system will automatically find matching driver installation online.
9, update the driver can choose online automatic update and manually specify the driver location update, the following chooses to manually specify the driver location update.
10. Click “Browse”.
11. Select the drive location directory and click OK.
12. Click “next”, the system will automatically install the selected driver, and the installation steps are completed.
Step 10, please select the directory where the device driver is placed according to the actual situation.
Mitsubishi PLC programming cable FX-USB-AW (USB-RS422) driver
Is there a usb SC09 fx win10 available version?
I have tried the same problem again. The result is: it can be used under XP system. You can wait for the new driver to back the new system or install the dual system or simply install the XP system. At present, there should be no W7 support. It is hardly able to use and is often disconnected.
GT01-C30R4-8P Suitable Mitsubishi F940/930/920 Series Touch Screen Connect Mitsubishi FX Series PLC FX-50DU-CAB0
FX-50DU-CAB0
Interface:9pin male-Round 8pins
Purpose: Suitable Mitsubishi GOT-F900 (F940/930/920)/GT1050 Touch Screen connect Mitsubishi FX Series PLC Programming Cable
Suitable GT11/GT15/GOT1040/GOT1050/GS Series Touch Panel as well.

FX-232-CAB-1 RS232 Port Cable Suitable Mitsubishi GOT-F900 920 930 940 GT1275 Touch Screen Programming Cable FX232CAB-1
FX-232-CAB-1
Interface: RS232-RS232
Cable Length: 2M
Purpose:RS232 Port Suitable Mitsubishi GOT-F900(F940/930/920)GT1275 Touch Screen programming Cable

Mitsubishi Q Series Programming Cable USB-Q Connect Mini Port USB-06UDEH Q03UDE Cable
USB-06UDEH
Suitable Mitsubishi Q Series Programming Cable USB-Q Connect Mini port
06UDEH/Q03UDE Programming Cable. Connect Mitsubishi Q Series PLC Mini port.

USB-FX232-CAB-1 Cable Suitable Mitsubishi F940 930 920 Touch Panel USB-FX232CAB-1
USB-FX232-CAB-1
Apply to USB Interface Mitsubishi F940/930/920 Touch panel programming Cale with indication lights, cable length around 2.5meters.
PC side: USB port
PLC side: 9pin Female port