What are the specific differences between Mitsubishi PLC FX3G series and FX3U series?

Mitsubishi FX3U series PLC processing speed industry leader, reached 0.065us/basic instructions, built-in 64K large capacity memory, greatly increased the number of internal soft components.
The transistor mainframe has built-in positioning function of up to 100kHz with three axes, and adds new positioning instructions: DSZR with DOG search, DVIT with interruption and TBL, which makes positioning control more powerful and more convenient to use. Up to 10 ADP special adapters can be connected to the left side of the PLC host. Including high-speed input and output adapters, analog input and output adapters and temperature input adapters, these adapters do not occupy system points. FX3U strengthens the instruction function and provides up to 209 application instructions, including communication with Mitsubishi frequency converter, CRC calculation, generating random numbers and so on. Enhanced communication function, its built-in programming interface can achieve 115.2 Kbps high-speed communication, and can expand two communication interfaces, such as RS-232, 422, 485, USB, Ethernet, MODBUS, etc.
FX3G series PLC is the third generation micro-programmable controller launched by Mitsubishi Motor, which is upgraded and developed on the basis of FX1N.
FX3G series PLC has 3-axis positioning function, multiple positioning instructions, and easy to set up. It is the preferred model to build servo/step positioning system.
FX3G series PLC host has two high-speed communication interfaces (RS422 USB) and built-in 32K memory. Two levels of password can be set, each level of 16 characters, which enhances the password protection function. In standard mode, the processing speed of basic instructions can reach 0.21 ugs, which can realize floating point arithmetic. The left side of basic unit can connect up to four FX3U special adapters.

What are the specific differences between Mitsubishi FX2N and FX3U PLC?

1. Operating speed, FX3U is the fastest.
2. Communication ports: FX3U can use three at the same time.
3. High-speed pulse output: FX3U series PLC can control three axes, one more axle than FX2N.
4. FX3U has more extension points than FX2N, and FX2N program can be directly imported into the same type of PLC of FX3U. It has no effect on the machine!
5. The biggest difference between FX3U and FX2N is that 3U has S/S terminal, through S/S terminal, PLC can be changed into leaky input or source input, FX2N does not have this function.

a50f4bfbfbedab64c55859a6fa36afc379311ea9
Expanded information:
FX2N is the choice of various applications from 16 to 256 input/output channels; FX2N series is miniaturized, high-speed, high-performance and all aspects are equivalent to the FX series of the highest-grade ultra-small program device. In addition to the independent use of 16-25 points input, it can also be applied to the connection between several basic components, analog control, positioning control and other special purposes. It is a set of PLC that can meet the wide variety of needs.
Connecting the expansion unit or expansion module on the basic unit, the flexible input-output combination of 16-256 points can be achieved. The host with 16/32/48/64/80/128 points can be selected, and the extension module with a minimum of 8 points can be used for expansion. It can be selected freely according to the power supply and output form.
Program capacity: Built-in 800-step RAM (input annotations) can use storage boxes, the maximum can be extended to 16K steps. There are many simple instructions, high-speed processing instructions, variable input filter constants, interruption of input processing, direct output and so on. Convenient instruction digital switch data reading, 16-bit data reading, matrix input reading, 7-segment display output, etc.
Data processing, data retrieval, data arrangement, trigonometric function operation, square root, floating-point decimal operation, etc. Special Purpose, Pulse Output, Pulse Width Modulation, PID Control Instruction, etc. External devices communicate with each other, serial data transmission, ASCII code printing, HEX ASCII transformation, check code, etc. The timer controls data comparison, addition, subtraction, reading and writing of built-in clocks.

Mitsubishi PLC connects Delta touch screen

Make sure that the communication module on Mitsubishi PLC is the 422 protocol.

Make sure that Delta’s touch screen program communication protocol is 422 protocol.

Prepare a serial cable.
Connect PLC and touch screen

Then you can communicate.

Be sure to ensure that the PLC is consistent with the touch screen communication protocol (protocol, baud rate, parity, etc.).

Can plc and touch screen communication lines be used as plc and computer programming lines?

Yes, for example FX-USB-AW USB interface Mitsubishi FX series PLC programming cable, USB/RS422 interface adapter, with communication indicator, length 3 meters
Mitsubishi FX3UC series PLC programming cable with FX-232AWC-H RS232 interface, RS232/RS422 interface adapter with communication indicator, length 3 meters
USB-QC30R2 USB interface Mitsubishi Q series PLC programming cable, USB/RS232 interface, cable length 3 m.

Mitsubishi PLC and Delta touch screen communication problems

See what plc, if it is 3u or you can use the convenience of 485 communication options, buy it, plug in 2 wires, and then communicate with Delta touch screen with 485.
Simply set the touch screen communication port to 422 mode. Solder the communication line according to the agreement. Finally, the touch screen is set to the same communication protocol as plc. If it is 485, remember the station number to find it.

Mitsubishi PLCFX3u and Delta touch screen communication problems

I want to let the PLC communicate with the Delta touch screen now, but I can’t communicate with any settings. The touch screen model is: DOP-B10S411. The PLC model is; FX3U-64MT. The touch screen communication parameters are set in this way: man-machine station number: 0 communication interface: RS232 data bit:

 

1, PLC does not need to be set
2. The communication protocol is set in the Delta touch screen (RS-422, 9600, E, 8, 1)
3, RS-422 communication line is connected, you can power on